Axiovert 25, Axiovert 25 C, Axiovert 25 CFL
08/99 B 40Ć012 e
1Ć18
1.5 Function elements
(see Figures 1Ć5, 1Ć6 and 1Ć7 following the table)
Item
No.
Designation Purposeā/ādescription
ă1 Microscope stand Support of the Axiovert 25 microscope
ă2 Auxiliary microscope For observation of the lens pupils and thus of phase
contrast and VAREL diaphragms
ă3 Diaphragm part, screwĆin Equipped with eyepiece measuring plate or format plate
for microphotography
ă4 Eyepiece, focusing Eyepiece for focusing the format reticule during
photograph or when using eyepiece measuring plates to
compensate for myopia for binocular observation
ă5 Binocular tube swivelling For insertion of eyepieces, adjustable to 2 heights and to
interpupillary distance
ă6 Eyepiece NonĆfocusing eyepiece
ă7 Monocular Adjustment aid when taking photographs with low
magnification factors
ă8 Specimen guide M
coaxial drive
For sensitive shifting of the inserted holding frames and
movement of specimens within a range of 130 x 85 mm
ă9 Specimen stage Stage area 210 x 290 mm; if required, replaceable by glass
stage or heating stage
10 Aperture diaphragm To change the illumination aperture via a lever
11 Phā/āHā/āPh slider Slider for triple phase contrast, left and right positions to
hold one ring diaphragm each, can be centered, middle
position with 42 mm attenuation filter
12 0.4 condenser Condenser with a 53 mm free working distance
13 Condenser change
position
Enables replacement of the 0.2 and 0.4 condensers
14 0.2 or 0.55 condenser Condenser with a 90 mm or 31 mm free working distance
15 Lighting unit 30 Microscope illumination with 6 V, 30 W halogen lamp,
with sliding condenser change position, free working
distance when condenser off 190 mm
16 Filter Conversion andā/āor attenuation filter
17 Filter slider Enables insertion of 32 mm light filters in the
observation beam path
18a Phā/āHā/āVar slider Slider for phase and VAREL contrast
Enables mounting of a ring diaphragm (phase contrast)
and of the VAREL diaphragm (HF, DF, VAREL contrast)
Middle position with 42 mm attenuation filter